Hewlett
Packard 408 Switch
|
|
|
|
|
- ideal for building small networks or connecting
peripherals with any combination of 10 Mbps and 100 Mbps
devices
- easy to use with HP Auto-MDIX on every port
- provides 8 autosensing 10/100 Ethernet ports
- Lifetime warranty for as long as you own the product!
Please
call Complete Computing at 501.372.3379 or 800.880.2949 for more
information or for a formal quote. |
|
Scroll down on
this page for all specifications..
|
Product
Name |
Part # |
DIS
Contract Price |
|
HP 408 Switch |
J4097B |
$72.00 |
|
|
|
 |
ports |
 |
 |
 |
8 RJ-45 10/100Base-TX ports
(IEEE 802.3 Type
10Base-T,
802.3u Type 100Base-TX)
all ports are HP Auto-MDIX |
 |
 |
address table size |
 |
 |
 |
| 1,000 entries |
 |
 |
physical characteristics |
 |
 |
 |
| dimensions: 19.9 x 12.1 x
4.0 cm (7.8 x 4.8 x 1.6 in) |
| weight: 0.7 kg (1.5 lb) |
 |
 |
memory & processor |
 |
 |
 |
| packet buffer size: 64 KB
per port |
| RAM/ROM capacity: 512 KB |
 |
| mounts in a standard 19-in
rack with optional |
| |
four-way mounting kit (ordered
separately) |
 |
|
 |
environment |
 |
 |
 |
| operating |
|
- temperature: 0°C to 55°C (32°F to 131°F)
- relative humidity: 15 to 95% @ 40°C (104°F),
noncondensing
|
| non-operating/storage |
|
- temperature: -40°C to 70°C (-40°F to 158°F)
- relative humidity: 90% @ 65°C (149°F),
noncondensing
|
| shock & vibration: EN 60068 (IEC 68) |
 |
 |
electrical characteristics |
 |
 |
 |
heat dissipation/hour: 52 BTU/hr
maximum wattage: 15 W (external power supply)
voltage: 110-127 VAC or 200-240 VAC
current: 0.4 A max/0.2 A max
frequency: 50/60 Hz |
 |
 |
communications |
 |
 |
 |
| IEEE 802.3x Flow Control |
 |
 |
safety |
 |
 |
 |
| EN 60950/IEC 950;UL 1950; CSA 950;
complies with NOM-019-SCFI-1994 |
 |
 |
emissions |
 |
 |
 |
| FCC Class A; EN 55022:1998/CISPR-22:1997
Class A; VCCI Class A |
 |
 |
immunity |
 |
 |
 |
EN 55024/CISPR 24
ESD: IEC 61000-4-2; 4kV CD, 8kV AD
radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0kV (power line), 0.5kV
(signal line)
surge: IEC 61000-4-5; 1kV/2kV AC, 1kV signal, 0.5kV
signal line
conducted: IEC 61000-4-6; 3V
power freq. magnetic field: IEC: 61000-4-8; 1A/m, 50 or
60 Hz
voltage dips or interruptions: IEC 61000-4-11; >95%
reduction: 0.5 periods,
30%
reduction: 25 periods
EN 61000-3-2/IEC 61000-3-2; harmonics
EN 61000-3-3/IEC 61000-3-3; flicker
|
|
|
|
|