Hewlett
Packard 23xx Switches
|
|
|
|
Scroll down on
this page for all specifications..
|
Product
Name |
Part # |
DIS
Contract Price |
|
HP Procurve 2324Switch (24 ports) |
J4818A |
$349.00 |
|
HP Procurve 2312 Switch (12 ports) |
J4817A |
$305.00 |
|
HP Procurve switch Gigabit stacking
kit |
J4116A |
$159.00 |
|
HP Procurve Gigabit SX transceiver |
J4131B |
$266.00 |
|
HP Procurve Gigabit LX transceiver |
J4132A |
$699.00 |
|
HP Procurve 100/1000-T transceiver |
J4834A |
$247.00 |
|
HP Procurve 100-FX SC transceiver |
J4853A |
$240.00 |
|
| switch 2324:
24 RJ-45 10/100Base-TX ports |
| |
(IEEE 802.3 Type 10Base-T; 802.3u Type
100Base-TX) |
switch 2312: 12 RJ-45 10/100Base-TX ports |
| |
(IEEE 802.3 Type 10Base-T; 802.3u Type
100Base-TX) |
both: two open transceiver slots; one RS-232C DB-9
download
port |
 |
 |
physical characteristics |
 |
 |
 |
| dimensions: 44.2 x 20.3 x
4.6 cm (17.4 x 8.0 x 1.8 in) |
| weight: 2.7 kg (6.0 lb) |
 |
 |
memory & processor |
 |
 |
 |
| packet buffer size: 6 MB
shared packet buffers |
| RAM/ROM capacity: 26 MB |
| processor type & speed:
ARM7TDMI @ 62.5 MHz |
| flash capacity: 2 MB |
 |
|
 |
mounting |
 |
 |
 |
| mounts in a standard 19-in rack
(hardware included) |
 |
 |
performance |
 |
 |
 |
latency: <10 µs (LIFO)
throughput: 6.6 million pps (64-byte packets)
switch fabric speed: 9.6 Gbps
address table size: 4,096 entries |
 |
 |
environment |
 |
 |
 |
| operating |
|
- temperature: 0°C to 55°C (32°F to 131°F)
- relative humidity: 15 to 95% @ 40°C (104°F),
noncondensing
|
| non-operating/storage |
|
- temperature: -40 °C to 70°C (-40°F to 158°F)
- relative humidity: 90% @ 65°C (149°F),
noncondensing
|
| shock & vibration: HP759, HP760 (similar
to EN 60068 IEC 68) |
 |
 |
electrical characteristics |
 |
 |
 |
heat dissipation/hour: 123 BTU/hr
maximum wattage: 36 W
voltage: 100-127 VAC/200-240 VAC
current: 2.4 A max/1.2 A max
frequency: 50/60 Hz |
 |
 |
communications |
 |
 |
 |
| IEEE 802.3x Flow Control |
 |
 |
safety |
 |
 |
 |
| EN 60950/IEC 950; UL 1950: CSA 950;
complies with NOM-019-SCFI-1994 |
 |
 |
emissions |
 |
 |
 |
| FCC Class A; EN 55022/CISPR-22 Class A;
VCCI Class A |
 |
 |
immunity |
 |
 |
 |
EN 55024/CISPR 24
ESD: IEC 61000-4-2; 4kV CD, 8kV AD
radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0kV (power line), 0.5kV
(signal line)
surge: IEC 61000-4-5; 1kV/2kV AC, 1kV signal, 0.5kV
signal line
conducted: IEC 61000-4-6; 3V
power freq. magnetic field: IEC: 61000-4-8; 1A/m, 50 or
60 Hz
voltage dips or interruptions: IEC 61000-4-11; >95%
reduction: 0.5 periods,
30%
reduction: 25 periods
EN 61000-3-2/IEC 61000-3-2; harmonics
EN 61000-3-3/IEC 61000-3-3; flicker |
|
|
|
|